Product Examples for application
Customer Specifications
Installed system must allow maximum operating speed without web breaks or transducer failures. Web breaks or downtime for system recalibration costs the manufacturer approximately $15,000.00 to $20,000.00 an hour.
Our Solution
We installed precision LTT Transducers with a high speed LCp-100 transmitter.
Temperature compensated LTT Transducers are gauged in a full Wheatstone Bridge configuration to eliminate signal drift and frequent recalibration requirements. Inherent scribe marks at 10° intervals permit the transducers to be rotated to the exact angle of web tension inclination for maximum measurement accuracy.
The high speed LCp-100 reads the transducer signals and updates the analogue output 120 times per second. High-speed updates facilitate constant machine operation at full speed.