Home - Stress Analysis Strain Gages - Calculators - Axial Column - 2 Gages In Opposite Arms (calculator): Transducer Output

Transducer Output

A calculator for

Axial Column - 2 Gages In Opposite Arms

Two active gages with equal strains of the same sign -- used on opposite sides of column with low thermal gradient (bending cancellation, for instance.)

Independent Variables
( Units for load and dimensions must coincide with those for elastic modulus. )
Load (lbf, etc.),
Elastic Modulus (lbf/in 2 , etc.),
Width (in, etc.),
Thickness (in, etc.),
Gage Factor (nondimensional),
Dependent Variable
Axial Strain (microstrain),
Bridge Output (mV/V),



Elastic Modulus:



Gage Factor:

If within the elastic range:


If the gage factor of the gage and instrument are the same:

Bridge Output